Priority Member Itrademarket Priority
1st Year
CV. DUTA MEDICA SARANA
CV. DUTA MEDICA SARANA
http://dumedpower.itrademarket.com
DAK BKKBN 2012 | SARANA PLKB 2012 | PUBLIC ADDRESS | OBGYN BED | IUD KIT | KIE KIT 2012 | IMPLANT KIT 2012 | BKB KIT + APE 2012 | MUPEN KB | MUYAN KB | DESKTOP PC
Company Contact
Name: Mr. Fuad Ahmad
[Marketing]
E-mail: dumedpower @yahoo .com
Homepage: http://www.dumedpower.co.id    Instant Messaging::
BlackBerry PIN: 22402D2E] 22402D2E
Phone Number: 021-34834914/ 021-94522310 Mobile Number: 0813-1590-4286 Fax Number: 021-3840608 Address: RSPAD GATOT SOEBROTO. (Wartel RSPAD Gatot Soebroto, Samping radiologi) Jl. KH. Abdul Rahman Saleh No.24 - Senen Telp : 021 34834914/94522310
Jakarta Pusat, Jakarta
Indonesia
ALAT KESEHATAN, DUTA MEDIKA SARANA, HOSPITAL ONLINE STORE
Average User Review

There is no review for this company

Write a review
Language: English Indonesia - Registration Date: Jan. 07, 2009 - Last Updated: Apr. 29, 2012

Sell

DEFIBRILLATOR ( CARDIAC RESUSCITATION ANDMONITORING SYSTEM + TROLLY) ME – D – 900 ( ECG / HR, PULSE, RESP & NIBP) WITH TROLLY, AC OPERATED
DEFIBRILLATOR

( CARDIAC RESUSCITATION ANDMONITORING SYSTEM + TROLLY)

ME – D – 900 ( ECG / HR, PULSE, RESP & NIBP) WITH TROLLY, AC OPERATED

MODEL M – E – D 900 DEFIBRILLATOR ( CARDIAC AND MONITORING SYSTEM) CONSISTS OF AN ECG AMPLIFIER, OSCILLOSCOPE, MANUAL – RECORDER, HEART RATE COUNTER AND DEFIRBILLATOR. THE SYSTEM IS NOT ONLY WITH THE NORMAL FUNCTION OF RECORDING AND DIS – PLAYING ECG, BUT ALSO WITH THAT OF AUTOMATICALLY ALARMING AND RECORDING BRADYCARDIA, TACHYCAR – DIA, VENTRICULAY TACHYCARDIA AND OTHER ABNORMAL RHYTHM. IT IS APPLICABLE TO THE CARDIAC RESUSCITATION OF DEFIBRILLATOR ON THE PATIENTS OF VENTRI – CULAR FIBRILLATION, A TRIAL FUTTER AND FIBRILLATION, ATRIAL OR VERTICULAR TACHYCARDIA OR HEART ARREST CAUSED BY ELECTRICAL SHOCK OR DROWNING WITH LESS BY – EFFECT. THERE FORE, IT IS WIDELY USED IN INTERNAL MEDICINE, CARDIOVASCULAR AND CHEST SURGERY, OPERATION ROOM, EMERGENCY ROOM, ICU, ECG EXERCISE TEST, PEDIATRICS WARDS AND IN AMBULACE, ETC.

Specifications:
• DISPLAY : “ 7 “ CRT MONITOR
• ECG : Input impedance ± 10M ohms and protect against DEFIBRILLATOR
shock
- CMRR : > 60dB
- ECG wave form : 0.25 ( G1) / 0.5 ( G2) … .. 1 ( G4) … … … 2( G8) mm / MV
- Frequency response : oscillography : 0.5 - 100Hz
Recording : 0.05 – 100Hz
- Sweep rate : 25 mm/ s
- Paper speed : 25 mm/ s and 50 mm/ s
- Heart rate : 25 – 250 bpm.
- Freeze, recall :
- Alarm : Heart rate upper 35 – 250 beats / minute
Lower 30 – 245 beats / minute
- Recording mode : Manual control

• NIBP : Measuring method : oscillometric method
Measuring unit : mm Hg / kpa

• RESP : R1, R2, R3, R4,
Alarm, freeze, record
• DEFIBRILLATOR :
- Discharge mode : a synchronize and synchronize
- Energy : External 0 – 200V
Internal 0 – 20V
- Power : 220 Volt 50 Hz 144 AV
- Pulse rate : 60 – 120 beats / minute
- Maximal charge time : d 20 second
- Maximal energy output : 360 joules